topleft
topright

Subscribe to our Newsletter




2 1

FAQ Service Bulletin ERROR 80 & 39
FAQ
Written by DJ Batchen   
Thursday, 04 February 2010 00:00
SERVICE BULLETIN
To: Service Agents and Distributors
From: Engineering: DJ Batchen
Re: Batchen T5 Error Codes 80 and 39




DETAILS
ERROR 80 Priority: Low
Cause : High Ambient Temperature
Error Description: PSU Card Offline

Description : This error will be seen on some dispensers under high ambient temperatures (+40). Mostly dispensers out in the open and not under a canopy.
Solution : Replace power supply board




ERROR 39 Priority: Low
Cause : High Ambient Temperature
Error Description : Eprom Error
Description : This error will be seen on some dispensers under high ambient temperatures (+40). Mostly dispensers out in the open and not under a canopy.
Solution : Upgrade Software to 1421 or later.

 